Precolumns (guard columns) and precolumn cartridges for HPLC. uhplcs guard columns. They are able to remove molecules which would form an irreversible bond with the material of the analytical column. Guard coloumns need to be changed on a regular basis. A good indication on when to change a precolumn is a gradual increase in the back pressure.

uHPLCs guard column assembly (guard holder + guard cartridge) combines the strength of stainless steel with the convenience and efficiency of a PEEK guard cartridge. A small section of the same packing as the column is placed between the injection valve and the column without using tools, which will extend the column’s life and ensure reproducible results.

Product Detail

FAQ

Product Tags

A guard column is installed between the injector and the analytical column in a high-performance liquid chromatograph, passing through the mobile phase and the sample solution. It can pre-trap substances that can be firmly adsorbed by the analytical HPLC column and cannot be washed by the mobile phase, protecting and extending the life of the analytical HPLC column.

 

 A 1 cm (i.e., 10 mm) long guard column will provide adequate protection for most liquid chromatographic analytical work. However, if the sample is dirty, or if it is found that the 1 cm guard column needs to be replaced frequently, then a 2 cm or 3 cm guard column should be used. The longer the guard column, the more chromatographic packing it naturally contains, and the better its protection performance. Of course, as the length of the guard column increases, the sample retention time increases accordingly. Generally speaking, the inner diameter of the guard column is the same or equivalent to the inner diameter of the analytical liquid chromatographic column.

 

Guard Column Cartridge Systems for HPLC accept cartridges of 4.6,3.0 or 10mm inner diameters – in either 4,10mm or 12mm lengths. Guard Cartridges are available with a comprehensive selection including all stationary phase chemistries offered by UHPLCS, ensuring compatibility between the guard column and the analytical column.  Assembly is tool-free, simplifying cartridge replacement.

 

Catalog number

Unit Size

Specification

Pore Size

HPDGK-046100-0000-0-000

Each

4.6# uhplcslab HPLC Guard Column

0.5μ, 2μ, 5μ, …

ARG Analytical Guard Columns

guard columnDSC_491723030101