Ghost Peaks Removing Column

Ghost Peaks Removing Column

Ghost Peaks Removing Column

Short Description:


Product Detail

FAQ

Product Tags

The Problem of Ghost Peaks
A vexing challenge in liquid chromatography analysis is the presence of ghost peaks. Ghost peaks are of unknown origin in chromatograms. They can be easily misidentified when close to the peak of interest. It can lead to quantitative errors when they overlap with the peak of interest. Of course, causes uncertainty in data quality and reliability. Worse, it is easy to spend much time identifying the source of obvious impurities, even when no impurities are associated with the compound of interest.

ghost peaks

Ghost Peaks in Reversed-Phase Analysis

The sources of ghost peaks are usually divided into three categories: those caused by impurities other than the target material, internal contamination of the LC instrument, and impurities in the mobile phase, as shown below.
(1) Impurities in the instrument
(2) Impurities in sample
(3) Impurities in the mobile phase

 

The Ghost Trap DS cartridges can be used to reduce or eliminate ghost peaks due to the mobile phase. Installing the Ghost Trap DS in the mobile phase flow line provides adsorption of the substances responsible for the ghost peaks, especially when conducting gradient elution with reversed phase analysis and a UV detector. Ghost peaks are prevented from appearing because the mobile phase is sent to the column after removing the problematic substances.
The Ghost Trap DS can be connected at various positions in the flow line according to the LC system configuration and the analysis application. 

 

Features: customization support | ready-to-ship supply | complete specifications adsorb and remove impurities from the mobile phase trap impurities in pipeline and mixer shorten the time of method validation and impurity analysis

 

Ghost Peaks Removing Cloumn

Products
Products

Catalog number

Product Name

Unit Size

Size

Dimensions

Maximum Pressure

HPGPG-021200-1-020

Ghost column cartridge

Each

2.1mmID*20mml

about 40μL

≦100MPa

HPGPG-040200-1-020

4.0mmID*20mml

about 150μL

≦35MPa

HPGPG-076300-1-020

7.6mmID*30mml

about 700μL

 

Highlights

  • Efficiently eliminates ghost peaks and baseline fluctuation.
  • Removes impurities from the mobile phase
  • Enables reliable and robust analysis of trace compounds

 